General Specifications

Solar Panel

  • Maximum Power (P max):  20 W
  • Voltage at Pmax (V mp):  17.3 V
  • Current at Pmax (IMP):  1.16 A
  • Short-Circuit Current (Isc):  1.29 A
  • Open-Circuit Voltage (Voc):  21.6 V

Solid State Regulator

Electrical Specifications:

  • Voltage:  12V
  • Rated Solar Input:  10A
  • Rated Load Current:  10A
  • Equalization Voltage:  14.8V
  • Boost Battery:  14.4V
  • Float Battery:  13.6V
  • Low Voltage Disconnect:  11.1V
  • Low Voltage Reconnect:  13.1V
  • Self-Consumption:  6 mA
  • Operating Temp.  -35 to +55ºC

Traffic Hazard Beacons

Polycarbonate Housing:

  • 12” light housing plastic injected molded polystyrene tufen u.v. impregnated material for ultra violet rays

LED:

  • Color:  Yellow/Amber
  • Applied Voltage:  12VDC
  • Power Consumption (watts):  5
  • • Dominant Wavelength (nm):   592
  • On Axis Luminous Intensity (Min):  350 cd
  • LEDs per signal lamp:  121
  • Intensity loss due to single LED failure:  1.21%
  • Operation Temperature:  -40°F to +165°F
  • Solid State Flasher/Timer Delay
  • Input voltage of 12 VDC
  • Flash rate 60 F.P.M.
  • Flash Delay can be set from 5-1270 seconds
  • Input voltage of 12 VDC (2 terminals)
  • Two outputs of 12 VDC (4 terminals)
  • Capable of switching 5 amps @ 12 VDC
  • Input and output terminals 1/4 male quick connect
  • Epoxy encapsulated construction
  • Flasher is 4″ x 2″, two outer mounting holes

Control Cabinet/Battery

  • Cabinet is 24” x 15” x 9”, .080, aluminum, “lockable”, to be located per state specifications.
  • Recommended battery shall be 100 amp deep cycle marine. (Options Available)
  • Signage and pole. (Options Available)

K & K Systems Transmitters

  • Size: 4 ½” x 2 3/8” x 7/8”
  • Range: 500 ft line of sight
  • Antenna: Ferrite
  • Output: 1.0 mW.
  • Frequency: 26.995 MHz. Crystal
  • Power: 9VDC NEDA battery
  • Current Consumption: +20mA
  • No. Codes: 6,561 in trinary format
  • Case: ABS Crushproof plastic

K & K Systems Receivers

  • Size: 3 1/8” x 2 ½” x 2” (base included)
  • Antenna: Tuned 26.995 MHz. Ground-plane
  • Output: Relay 1A. at 120 VAC, 2A. at 30 VDC
  • Power: 11.8 – 26.0 VDC or 17.8 – 26.0 VDC
  • Current Consumption: 30mA. Idle, 60 mA. Alarm

Push Button Assembly

  • 2” Button with momentary switch rated at 36VDC
  • 5” x 7” button fixture with crossing sign inserted